News

News

Home>News>Content

How To Maintain And Upkeep The Water Pump For Better Use

Jan 01, 2026

In order to ensure the normal use and service life of submersible sewage pumps, regular inspections and maintenance should be carried out:
1. Replace the sealing ring: After long-term use in sewage medium, the gap between the impeller and the sealing ring may increase, causing a decrease in water pump flow and efficiency. The electric switch should be turned off, the water pump should be lifted, the bottom cover should be removed, the sealing ring should be removed, and the sealing ring should be matched according to the actual size of the impeller mouth ring. The gap is generally around 0.5mm.
2. When the submersible sewage pump is not used for a long time, it should be cleaned and lifted in a ventilated and dry place, and attention should be paid to antifreeze. If placed in water, run for at least 30 minutes every 15 days (without dry grinding) to check its functionality and adaptability.
3. The cable should be inspected at least once a year, and if it is damaged, it should be replaced.
4. Check the motor insulation and fastening screws at least once a year. If the motor insulation decreases, please contact the manufacturer. If the fastening screws become loose, please tighten them again.

 

null


5. The submersible sewage pump has been injected with an appropriate amount of engine oil (32 mechanical oil) before leaving the factory to lubricate the mechanical seal. This engine oil should be checked once a year. If water is found in the engine oil, it should be drained, the engine oil should be replaced, the sealing gasket should be replaced, and the screw plug should be tightened. After three weeks, it is necessary to recheck. If the oil becomes emulsified again, the mechanical seal should be inspected and replaced if necessary.
6. After a malfunction occurs in the operation of the submersible sewage pump, please follow the provided troubleshooting methods to eliminate it. If the problem still cannot be solved and the cause cannot be determined, do not dismantle or repair it without authorization. Contact the manufacturer immediately.